Pennsylvania Department of Health
MAYBROOK HILLS REHABILITATION AND HEALTHCARE CENTER
Building Inspection Results

Note: If you need to change the font size, click the "View" menu at the top of the page, place the mouse over the "Text Size" menu item, and select the desired font size.

Severity Designations

Click here for definitions Click here for definitions Click here for definitions Click here for definitions
Minimal Citation - No Harm Minimal Harm Actual Harm Serious Harm
MAYBROOK HILLS REHABILITATION AND HEALTHCARE CENTER
Inspection Results For:

There are  58 surveys for this facility. Please select a date to view the survey results.

Surveys don't appear on this website until at least 41 days have elapsed since the exit date of the survey.
MAYBROOK HILLS REHABILITATION AND HEALTHCARE CENTER - Inspection Results Scope of Citation
Number of Residents Affected
By Deficient Practice
Initial comments:Name: - Component: -- - Tag: 0000


Based on an Emergency Preparedness Survey completed on September 8-9, 2026, at Maybrook Hills Rehabilitation and Healthcare Center, it was determined there were no deficiencies identified with the requirements of 42 CFR 483.73.





 Plan of Correction:


Initial comments:Name: MAIN BUILDING 01 - Component: 01 - Tag: 0000


Facility ID #480502
Component 01
Main Building

Based on a Medicare/Medicaid Recertification Survey conducted on September 8-9, 2026, it was determined that Maybrook Hills Rehabilitation and Healthcare Center was not in compliance with the following requirements of the Life Safety Code for an existing health care occupancy. Compliance with the National Fire Protection Association's Life Safety Code is required by 42 CFR 483.90(a).

This is a three-story, Type II (111), protected, non-combustible building, without a basement, that is fully sprinklered.





 Plan of Correction:


NFPA 101 STANDARD Sprinkler System - Maintenance and Testing:This is a less serious (but not lowest level) deficiency and affects more than a limited number of residents, staff, or occurrences. This deficiency is one that results in minimal discomfort to the resident or has the potential (not yet realized) to negatively affect the resident's ability to achieve his/her highest functional status. This deficiency was not found to be throughout this facility.
Sprinkler System - Maintenance and Testing
Automatic sprinkler and standpipe systems are inspected, tested, and maintained in accordance with NFPA 25, Standard for the Inspection, Testing, and Maintaining of Water-based Fire Protection Systems. Records of system design, maintenance, inspection and testing are maintained in a secure location and readily available.
a) Date sprinkler system last checked _____________________
b) Who provided system test ____________________________
c) Water system supply source __________________________
Provide in REMARKS information on coverage for any non-required or partial automatic sprinkler system.
9.7.5, 9.7.7, 9.7.8, and NFPA 25
Observations:
Name: MAIN BUILDING 01 - Component: 01 - Tag: 0353

Based on observation and interview, the facility failed to maintain the automatic sprinkler system in two instances, affecting two of eighteen smoke compartments.

Findings include:

Observation on September 8-9, 2026, revealed the following deficiencies, which may affect the operation of the automatic sprinkler system:

a) 10:00 a.m., There were two penetrations above the ceiling tile by the stairs to the behavioral health unit;
b) 11:00 a.m., There were two missing drop ceiling tiles in the activity director's office.

Interview with the facility administrator and maintenance director on September 9, 2026, at 11:30 a.m., confirmed the automatic sprinkler system deficiencies.







 Plan of Correction - To be completed: 09/25/2026

The two penetrations above the ceiling tile by the stairs to the behavioral health unit were repaired the day of survey. Also, the two missing drop ceiling tiles in the Activity Director's office were replaced the day of survey.

These were isolated issues and no other areas are affected.

Director of Maintenance will re-educate maintenance staff on these issues. Director of Maintenance will complete an audit of 3 random areas weekly x 4 then monthly x 2 to ensure compliance is met and maintained.

Findings will be reviewed at the monthly facility Quality Assurance and Performance Improvement meeting to determine continued frequency of audits.