MORRISONS COVE HOME - Inspection Results Scope of Citation
Number of Residents Affected
By Deficient Practice
Initial comments:Based on a  complaint survey completed on July 20, 2026, it was determined that Morrisons Cove Home was not in compliance with the following requirements of 42 CFR Part 483, Subpart B, Requirements for Long Term Care Facilities and the 28 PA Code, Commonwealth of Pennsylvania Long Term Care Licensure Regulations.

 


 Plan of Correction:


483.45(f)(2) REQUIREMENT Residents are Free of Significant Med Errors:This is a less serious (but not lowest level) deficiency and is isolated to the fewest number of residents, staff, or occurrences. This deficiency is one that results in minimal discomfort to the resident or has the potential (not yet realized) to negatively affect the resident's ability to achieve his/her highest functional status.
The facility must ensure that its-
§483.45(f)(2) Residents are free of any significant medication errors.
Observations:

Based on review of facility policy and clinical records, as well as staff interviews, it was determined that the facility failed to ensure that residents were free from significant medication errors for one of 5 residents reviewed (Resident 1). This deficiency is being cited as past non-compliance.


Findings include:

A facility policy for glucose monitoring dated January 27, 2026, indicated that glucose meter checks are obtained per physician's order or as needed if resident is displaying signs and symptoms of hypoglycemia or hyperglycemia.

Resident 1's clinical record revealed that the resident was admitted on June 17, 2026, with a diagnosis of Diabetes. Physician's orders for Resident 1, dated June 17, 2026, included orders for the resident to receive insulin lispro (a rapid acting insulin that lowers blood sugar in 10-15 minutes) 100 unit/milliliter, inject per sliding scale if blood sugar is 141-180 milligrams/deciliter (mg/dL)= 2 units, 181-220 mg/dL = 4 units, 221-260 mg/dL= 6 units, 261-300 mg/dL = 8 units, 301-340 mg/dL = 12 units before meals. Current manufacturer's instructions for inulin lispro100 unit/milliliter indicate to inject medication 5-10 minutes prior to eating.

The facility's meal delivery schedule for South Hall revealed that dinner trays were to arrive at 5:00 p.m. daily.

A review of the Medication Administration Record (MAR) for Resident 1 on June 22, 2026, revealed that LPN 1checked the resident's blood glucose at 3:57 p.m., it was 149 mg/dL and she administered 2 units of insulin lispro (63 minutes before the scheduled dinner meal).

A review of Resident 1's meal intake for dinner at 5:00 p.m. on June 22, 2026, revealed the resident ate zero percent of the meal.

A nursing note for Resident 1 dated June 22, 2026, at 8:30 p.m. revealed that the resident was found unresponsive in his room and 911 was called. The resident's blood sugar was rechecked by EMS at 8:45 p.m. and was 47mg/dL.

An incident report for Resident 1, dated June 24, 2026, confirmed that dinner trays were not provided on June 22, 2026, until 5:00 p.m., and that LPN 1 did not recheck the resident's blood sugar.

An interview with the Director of Nursing on July 20, 2026, confirmed that LPN 1 did not administer the insulin at the appropriate time per manufacturer's instructions.

Following the incident on June 22, 2026, the facility's corrective actions included:

1. On June 22, 2026, at 8:30 p.m. the resident was assessed, the Medical Director and the Resident Representative were notified. EMS was notified and the resident was evaluated and sent to the Emergency Room. On June 23, 2026, LPN1 was educated on site for medication and hypoglycemia and subsequently terminated as a result of the incident.

2. Education records, dated June 23, 2026, revealed that all of the facility's nursing staff received education regarding the facility's hypoglycemia (low blood sugar) and hyperglycemia (high blood sugar) policy and manufacturer's instructions for insulin.

4. The Director of Nursing or designee will audit treatments to ensure that resident's on sliding scale insulin is administered per policy and protocol for five days a week for one week, and then three days a week for one week and then weekly for one month. Further audits will be completed as determined by the Quality Assurance Performance Improvement (QAPI) committee

Review of the facility's corrective actions and interviews completed with staff regarding their re-education revealed that they were in compliance with F760 on July 23, 2026.

28 Pa. Code 211.12(d)(5) Nursing services.

28 Pa. Code 211.12(d)(1)(5) Nursing Services.







 Plan of Correction - To be completed: 08/04/2026

Past noncompliance: no plan of correction required.