Pennsylvania Department of Health
HAVEN PLACE REHABILITATION AND NURSING CENTER
Building Inspection Results

Note: If you need to change the font size, click the "View" menu at the top of the page, place the mouse over the "Text Size" menu item, and select the desired font size.

Severity Designations

Click here for definitions Click here for definitions Click here for definitions Click here for definitions
Minimal Citation - No Harm Minimal Harm Actual Harm Serious Harm
HAVEN PLACE REHABILITATION AND NURSING CENTER
Inspection Results For:

There are  47 surveys for this facility. Please select a date to view the survey results.

Surveys don't appear on this website until at least 41 days have elapsed since the exit date of the survey.
HAVEN PLACE REHABILITATION AND NURSING CENTER - Inspection Results Scope of Citation
Number of Residents Affected
By Deficient Practice
Initial comments:Name: - Component: -- - Tag: 0000


Based on an Emergency Preparedness Survey completed on September 14, 2026, at Haven Place Rehabilitation and Nursing Center, it was determined there were no deficiencies identified with the requirements of 42 CFR 483.73.





 Plan of Correction:


Initial comments:Name: MAIN BUILDING 01 - Component: 01 - Tag: 0000


Facility ID #122202
Component 01
Building 01

Based on a Medicare/Medicaid Recertification Survey completed on September 14, 2026, it was determined that Haven Place Rehabilitation and Nursing Center was not in compliance with the following requirements of the Life Safety Code for an existing health care occupancy. Compliance with the National Fire Protection Association's Life Safety Code is required by 42 CFR 483.70(a).

This is a three story, Type II (222), fire resistive building, with a partial basement, that is fully sprinklered.





 Plan of Correction:


NFPA 101 STANDARD Building Construction Type and Height:This is a less serious (but not lowest level) deficiency and affects more than a limited number of residents, staff, or occurrences. This deficiency is one that results in minimal discomfort to the resident or has the potential (not yet realized) to negatively affect the resident's ability to achieve his/her highest functional status. This deficiency was not found to be throughout this facility.
Building Construction Type and Height
2012 EXISTING
Building construction type and stories meets Table 19.1.6.1, unless otherwise permitted by 19.1.6.2 through 19.1.6.7
19.1.6.4, 19.1.6.5

Construction Type
1 I (442), I (332), II (222) Any number of stories
non-sprinklered and sprinklered

2 II (111) One story non-sprinklered
Maximum 3 stories sprinklered

3 II (000) Not allowed non-sprinklered
4 III (211) Maximum 2 stories sprinklered
5 IV (2HH)
6 V (111)

7 III (200) Not allowed non-sprinklered
8 V (000) Maximum 1 story sprinklered
Sprinklered stories must be sprinklered throughout by an approved, supervised automatic system in accordance with section 9.7. (See 19.3.5)
Give a brief description, in REMARKS, of the construction, the number of stories, including basements, floors on which patients are located, location of smoke or fire barriers and dates of approval. Complete sketch or attach small floor plan of the building as appropriate.
Observations:
Name: MAIN BUILDING 01 - Component: 01 - Tag: 0161

Based on observation and interview, it was determined the facility failed to maintain building construction requirements in three instances, affecting one of four floors.

Findings include:

1. Observation on September 14, 2026, between 10:12 a.m., and 10:26 a.m., revealed the following:

a. 10:12-10:20 a.m., missing ceiling tiles, located within the Breakroom and within the non-use, first floor UPMC Suite area.
b. 10:16 a.m., portable air conditioning exhaust duct work vented into interstitial space within the UPMC office and lacked fire damper.
c. 10:26 a.m., two, non-rated, ceiling-mounted drip trays were located within the first floor, Therapy.

Exit interview on September 14, 2026, between 11:20 a.m., and 11:30 a.m., with the Facility Administrator and the Facilities Manager, confirmed the building construction deficiencies.





 Plan of Correction - To be completed: 10/10/2026

1. Missing ceiling tiles were replaced with appropriate ceiling tiles of the required type and rating for the affected areas. . The exhaust duct will be appropriately terminated or the equipment will be relocated/removed as necessary. The drip trays will be removed or replaced with appropriately approved/rated equipment as determined by the facility's qualified maintenance personnel and/or qualified contractor.

2. The Director of Maintenance or designee conducted a facility-wide inspection of all resident care areas, common areas, offices, therapy areas, mechanical/interstitial areas, and other applicable areas to identify:
Missing or damaged ceiling tiles and
Improper ceiling penetrations

3. The Director of Maintenance or designee will ensure that the facility's routine Life Safety rounds include inspection of Ceiling tiles and ceiling systems.

4. Maintenance staff will be educated on when doing life safety rounds to ensure ceiling tiles are in place.

5. The Director of Maintenance or designee will complete a weekly Life Safety building construction audit for four consecutive weeks to ensure ceiling tiles are not missing and there is no improper ceiling penetrations. If deficiencies are found they will be addressed immediately and results of audit will be reviewed monthly during QAPI


NFPA 101 STANDARD Portable Fire Extinguishers:This is a less serious (but not lowest level) deficiency and is isolated to the fewest number of residents, staff, or occurrences. This deficiency is one that results in minimal discomfort to the resident or has the potential (not yet realized) to negatively affect the resident's ability to achieve his/her highest functional status.
Portable Fire Extinguishers
Portable fire extinguishers are selected, installed, inspected, and maintained in accordance with NFPA 10, Standard for Portable Fire Extinguishers.
18.3.5.12, 19.3.5.12, NFPA 10
Observations:
Name: MAIN BUILDING 01 - Component: 01 - Tag: 0355

Based on observation and interview, it was determined the facility failed to maintain portable fire extinguishers in multiple locations, affecting three of four floor.

Findings include:

1. Observation on September 14, 2026, between 10:15 a.m., and 11:05 a.m., revealed multiple flush-mounted fire extinguishers lacked the protective cover plate portion of the assemblies. Located at first, second, and third floor levels, in various locations.

Exit interview on September 14, 2026, between 11:20 a.m., and 11:30 a.m., with the Facility Administrator and the Facilities Manager, confirmed the portable fire extinguisher deficiencies.




 Plan of Correction - To be completed: 10/10/2026

1. The facility immediately reviewed the portable fire extinguishers identified during the survey on the first, second, and third floors.
The missing protective cover plates associated with the flush-mounted fire extinguisher assemblies were identified and reported to the Director of Maintenance for immediate correction.

2. Because the finding involved multiple floors, the Director of Maintenance or designee will conduct a 100% facility-wide inspection of all portable fire extinguishers and associated mounting/flush-mounted assemblies.

3. The facility will revise its routine Life Safety inspection process to specifically include inspection of the complete portable fire extinguisher assembly, including protective cover plates associated with flush-mounted installations. New covers were purchase to replace the ones that were missing.

4. The Director of Maintenance or designee will educate Maintenance staff regarding:
- NFPA requirements applicable to portable fire extinguishers;
- Proper mounting and accessibility requirements;

5. The Director of Maintenance or designee will conduct an inspection of all portable fire extinguishers weekly for four consecutive weeks. Results will be reviewed monthly in QAPI.
NFPA 101 STANDARD Fire Drills:Least serious deficiency but was found to be widespread throughout the facility and/or has the potential to affect a large portion or all the residents. This deficiency has the potential for causing no more than a minor negative impact on the resident.
Fire Drills
Fire drills include the transmission of a fire alarm signal and simulation of emergency fire conditions. Fire drills are held at expected and unexpected times under varying conditions, at least quarterly on each shift. The staff is familiar with procedures and is aware that drills are part of established routine. Where drills are conducted between 9:00 PM and 6:00 AM, a coded announcement may be used instead of audible alarms.
19.7.1.4 through 19.7.1.7
Observations:
Name: MAIN BUILDING 01 - Component: 01 - Tag: 0712

Based on documentation review and interview, it was determined the facility failed to maintain fire drills in eight of twelve instances, affecting four of four floors.

Findings include:

1. Observation on September 14, 2026, at 10:00 a.m., revealed eight of twelve required fire drills (for the previous twelve month period), were conducted during the last week of each respective month.

Exit interview on September 14, 2026, between 11:20 a.m., and 11:30 a.m., with the Facility Administrator and the Facilities Manager, confirmed the fire drill deficiencies.




 Plan of Correction - To be completed: 10/10/2026

1. The facility recognizes the requirement to conduct fire drills at expected and unexpected times and under varying conditions, at least quarterly on each shift.

2. All residents and staff have the potential to be affected by the deficient practice because fire drills are facility-wide Life Safety requirements.
The Administrator and Director of Maintenance/designee will review the facility's fire drill schedule for the upcoming twelve-month period to ensure that the required drills are appropriately distributed across all shifts.

3. The Director of Maintenance or designee will prepare the annual fire drill schedule with sufficient variation to prevent a predictable pattern.

4. Staff will be educated regarding the purpose of fire drills and the requirement that drills be conducted at varying and unexpected times to ensure staff remain familiar with emergency procedures and can respond appropriately.

5. The Director of Maintenance or designee will audit the fire drill schedule and documentation monthly for six months. results will be reviewed monthly at QAPI.