§483.25(e) Incontinence. §483.25(e)(1) The facility must ensure that resident who is continent of bladder and bowel on admission receives services and assistance to maintain continence unless his or her clinical condition is or becomes such that continence is not possible to maintain.
§483.25(e)(2)For a resident with urinary incontinence, based on the resident's comprehensive assessment, the facility must ensure that- (i) A resident who enters the facility without an indwelling catheter is not catheterized unless the resident's clinical condition demonstrates that catheterization was necessary; (ii) A resident who enters the facility with an indwelling catheter or subsequently receives one is assessed for removal of the catheter as soon as possible unless the resident's clinical condition demonstrates that catheterization is necessary; and (iii) A resident who is incontinent of bladder receives appropriate treatment and services to prevent urinary tract infections and to restore continence to the extent possible.
§483.25(e)(3) For a resident with fecal incontinence, based on the resident's comprehensive assessment, the facility must ensure that a resident who is incontinent of bowel receives appropriate treatment and services to restore as much normal bowel function as possible.
|
Observations:
Based on review facility policies, clinical record review, and staff interviews it was determined that the facility failed to make certain that appropriate treatments and services were provided for a resident with a suspected urinary tract infection for one of four residents (Resident R1).
Findings include:
Review of the facility "Urinary Tract Infection (UTI)" last reviewed January 2026, indicated the facility "Will provide appropriate assessment, prevention, identification, management, and monitoring of urinary tract infections."
Review of the clinical record revealed that Resident R1 was admitted to the facility on 1/2/24.
Review of Resident R1's Minimum Data Set (MDS, periodic assessment of resident care needs) dated 6/25/26, included diagnoses of heart failure (a progressive heart disease that affects pumping action of the heart muscles), diabetes (a metabolic disorder in which the body has high sugar levels for prolonged periods of time), and dementia (a group of symptoms that affects memory, thinking and interferes with daily life). Review of Section H: Bladder and Bowel, indicated Resident R1 was frequently incontinent of urine.
Review of the plan of care for urinary incontinence initiated 1/10/24, indicated for staff to, "Report S&;S (signs and symptoms) of UTI such as flank pain, c/o burning/pain, fever, hematuria, change in mental status, etc."
Review of a progress note dated 6/26/26, at 9:09 a.m. indicated, "Resident is making delusional comments and stories. Seemed to be more confused. Refused to attend ice cream social yesterday and was in bed most of the day. Odd behavior for her. Reported to nursing Supervisors, discussed in clinical."
Review of a physiatry progress note dated 6/30/26, at 12:21 p.m. indicated, "Findings were discussed with the primary nurse practitioner, with recommendation for urinalysis and treatment of a urinary tract infection (UTI) if urinalysis is positive."
Review of a physician's assistant progress note dated 7/1/26, at 10:41 a.m. indicated, "Patient sates that she has noticed a "foul smell from down below" but is unsure where it is coming from. She states that she has been urinating more frequently." The note further stated a plan for, "UA (urinalysis, a test that looks for signs of infection or inflammation) with reflex culture (a urine culture test to completed if the urinalysis is positive) to rule out infection."
Review of the clinical record indicated that the order for the urinalysis was documented as completed on 7/2/26. Further review of the clinical record failed to reveal documentation that the urine was processed, received by the lab, or any results available from the documented urine test.
Review of a "change in condition" progress note dated 7/4/26, at 7:37 p.m. indicated Resident R1 was demonstrating increased confusion, greater need for assistance with activities of daily living, and generalized weakness.
Review of a progress note dated 7/5/26, at 10:15 p.m. indicated a urine specimen was collected.
Review of a progress note dated 7/8/26, at 12:54 p.m. indicated that Resident R1 has E.coli (type of bacteria that lives in the intestines) present. "[Resident R1] states that she continues to have foul smelling urine and intermittently pain with urination."
Review of a physician's order dated 7/8/26, indicated, Fosfomycin Tromethamine (single-dose, oral antibiotic prescribed to treat uncomplicated urinary tract infections) Oral Packet 3 gram. Give 1 packet by mouth one time a day for UTI for 1 Day.
Review of a progress note dated 7/8/26, at 10:07 p.m. indicated that the Fosfomycin was unavailable, "awaiting pharmacy arrival."
Review of a "change in condition" progress note dated 7/8/26, at 11:00 p.m. indicated Resident R1 was experiencing increased urinary incontinence.
Review of a physician's note dated 7/10/26, at 8:33 a.m. indicated that Resident R1 had received her dose of fosfomycin and additionally received one liter of fluid, intravenously.
Review of Resident R1's medication administration record (MAR) for July 2026 failed to reveal that Resident R1 received the medication or liter of fluid at the time of the progress note on 7/10/26, at 8:33 a.m.
Review of a progress note dated 7/13/26, at 2:42 p.m. indicated that Resident R1 the administration of fosfomycin.
During an interview on 8/21/26, at approximately 2:00 p.m. the Infection Preventionist confirmed the lack of treatment for Resident R1's urinary tract infection from the onset of symptoms (6/26/26) until medication administration on 7/13/26.
During an interview on 8/21/26, at approximately 2:05 p.m. the Nursing Home Administrator confirmed the facility failed to make certain that appropriate treatments and services were provided for a resident with a suspected urinary tract infection for one of four residents.
28 Pa. Code: 201.14(a) Responsibility of licensee. 28 Pa. Code: 211.10(c)(d) Resident care policies. 28 Pa. Code: 211.12(d)(1)(2)(3)(5) Nursing services.
| | Plan of Correction - To be completed: 09/29/2026
Cited: Resident has completed course of antibiotics and reassessed by provider and has returned to baseline. Like: Current residents with s/sx of suspected UTI's have been reviewed by the providers with Labs/treatments initiated as ordered and current stock of ATB's in house for any additions needed. Education: Licensed nursing staff/CRNP's/PA's have been educated by the DON/designee on treatment initiation and time frames for residents with suspected UTI's. Monitoring: Residents with suspected UTI's will be reviewed by the DON/designee to ensure prompt initiation of treatment as recommended by the resident's provider. Audits will be completed three times a week for two weeks then weekly times four with results reviewed at QA for corrective action as deemed necessary.
|
|