Pennsylvania Department of Health
WINDBER WOODS SENIOR LIVING & REHABILITATION CENTER
Patient Care Inspection Results

Note: If you need to change the font size, click the "View" menu at the top of the page, place the mouse over the "Text Size" menu item, and select the desired font size.

Severity Designations

Click here for definitions Click here for definitions Click here for definitions Click here for definitions
Minimal Citation - No Harm Minimal Harm Actual Harm Serious Harm
WINDBER WOODS SENIOR LIVING & REHABILITATION CENTER
Inspection Results For:

There are  115 surveys for this facility. Please select a date to view the survey results.

Surveys don't appear on this website until at least 41 days have elapsed since the exit date of the survey.
WINDBER WOODS SENIOR LIVING & REHABILITATION CENTER - Inspection Results Scope of Citation
Number of Residents Affected
By Deficient Practice
Initial comments:


Based on a complaint survey completed on March 11, 2024, it was determined that Windber Woods Senior Living and Rehabilitation Center was not in compliance with the following requirements of 42 CFR Part 483, Subpart B, Requirements for Long Term Care Facilities and the 28 PA Code, Commonwealth of Pennsylvania Long Term Care Licensure Regulations.


 Plan of Correction:


483.21(b)(3)(i) REQUIREMENT Services Provided Meet Professional Standards:This is a less serious (but not lowest level) deficiency and is isolated to the fewest number of residents, staff, or occurrences. This deficiency is one that results in minimal discomfort to the resident or has the potential (not yet realized) to negatively affect the resident's ability to achieve his/her highest functional status.
§483.21(b)(3) Comprehensive Care Plans
The services provided or arranged by the facility, as outlined by the comprehensive care plan, must-
(i) Meet professional standards of quality.
Observations:


Based on review of Pennsylvania's Nursing Practice Act, residents' clinical records, personnel files, and the licensed practical nurse job description, as well as staff interviews, it was determined that the facility failed to ensure that the nurse documented treatments accurately for one of 10 residents reviewed (Resident 6). This deficiency was cited as past non-compliance.

Findings include:

The Pennsylvania Code, Title 49, Professional and Vocational Standards, State Board of Nursing, 21.148. Standards of nursing conduct (a)(5)(8) indicated that the licensed practical nurse was to document and maintain accurate records. Not to falsify or knowingly make incorrect entries into the patient's record or other related documents.

The facility's licensed practical nurse job description, dated May 8, 2018, revealed that the licensed practical nurse was to chart nurses' notes in an informative and descriptive manner that reflects the care provided to the resident, as well as the resident's response to the care, and perform routine charting duties as required and in accordance with the facility's established charting and documentation policies and procedures.

Physician's order for Resident 6, dated January 10, 2024, revealed that staff were to cleanse the resident's left shin with wound cleanser, then apply Xeroform gauze (a sterile, non-adhering protective dressing consisting of absorbent, fine-mesh gauze impregnated with a petrolatum), and secure with border foam dressing (a highly absorbent self-adherent silicone foam dressing) every other day and as needed on dayshift for an abrasion (an area damaged by scraping or wearing away).

A review of Resident 6's January 2024 Treatment Administration Record (TAR) revealed that Licensed Practical Nurse 1 documented as having completed the treatment to Resident 6's left shin on January 14, 2024.

However, a review of Licensed Practical Nurse 1's personnel file revealed a disciplinary action, dated January 15, 2024, indicating that on the morning of January 15, 2024, as the wound nurse was completing treatments on Resident 6 and it was noted that the resident had an intact dressing on the left lower leg dated January 12, 2024. According to physician's orders, the treatment to Resident 6's left lower leg wound was ordered for every other day, on day shift (7:00 a.m. to 3:00 p.m.) and should have been completed on January 14, 2024. However, as noted by the intact dressing, this treatment was not performed since January 12, 2024. Upon further investigation, Resident 6's TAR indicated that the treatment had been completed by Licensed Practical Nurse 1 on January 14, 2024.

Interview with the Nursing Home Administrator on March 11, 2024, at 4:00 p.m. confirmed that Licensed Practical Nurse 1 did not complete Resident 6's treatment as ordered on January 14, 2024, and confirmed that she documented the treatment as being completed on the resident's TAR.

Following the investigation on January 15, 2024, the facility's corrective actions included:

Licensed Practical Nurse 1 was re-educated on professional standards related to completing treatments as ordered and accurate documentation.

A whole-house wound treatment assessment was completed on residents to identify any issues.

Staff education on the completion of treatments as ordered and documentation was completed.

Audits were being completed to identify any wound treatment/documentation issues.

The results of these audits will be brought to Quality Assurance Performance Improvement committee for further analysis and corrective actions if necessary.

Review of the facility's corrective actions revealed that they were in compliance with F658 on March 4, 2024.

28 Pa. Code 211.12(d)(1)(5) Nursing Services.




 Plan of Correction - To be completed: 03/25/2024

Past noncompliance: no plan of correction required.
483.25 REQUIREMENT Quality of Care:This is a less serious (but not lowest level) deficiency and is isolated to the fewest number of residents, staff, or occurrences. This deficiency is one that results in minimal discomfort to the resident or has the potential (not yet realized) to negatively affect the resident's ability to achieve his/her highest functional status.
§ 483.25 Quality of care
Quality of care is a fundamental principle that applies to all treatment and care provided to facility residents. Based on the comprehensive assessment of a resident, the facility must ensure that residents receive treatment and care in accordance with professional standards of practice, the comprehensive person-centered care plan, and the residents' choices.
Observations:


Based on review of clinical records and personnel files, as well as staff interviews, it was determined that the facility failed to ensure that residents received care and treatment in accordance with professional standards of practice by failing to ensure that physician's orders were followed for two of 10 residents reviewed (Residents 4, 6).

Findings include:

A physician's progress note, dated January 25, 2024, revealed that Resident 4 was seen for a rash on his back that began suddenly and was itchy and red. The plan was to apply 0.025 percent Triamcinolone cream to the rash twice a day; however, there was no physician's order that included the recommended treatment.

A review of Resident 4's Treatment Administration Record (TAR) for January and February 2024 revealed that there was no documented evidence that Triamcinolone cream was applied to the resident's rash as recommended by the physician.

Interview with Registered Nurse 2 on March 11, 2024, at 2:58 p.m. confirmed that she missed the physician's order and did not enter it into the electric medical record.

Interview with the Nursing Home Administrator on March 11, 2024, at 2:50 p.m. confirmed that Resident 4 did not receive Triamcinolone to the rash on his back as recommended by the physician on January 25, 2024.


A care plan for Resident 6, dated January 31, 2024, revealed that the resident had a potential for pressure ulcer (areas of damage to the skin and the tissue underneath) development and staff were to complete treatments as ordered.

Physician's orders for Resident 6, dated January 10, 2024, revealed that staff were to cleanse the resident's left shin with wound cleanser, then apply Xeroform gauze (a sterile, non-adhering protective dressing consisting of absorbent, fine-mesh gauze impregnated with a petrolatum), and secure with border foam dressing (a highly absorbent self-adherent silicone foam dressing) every other day and as needed on dayshift for an abrasion (an area damaged by scraping or wearing away).

Review of Licensed Practical Nurse 1's personnel file revealed a disciplinary action, dated January 15, 2024, which indicated that on the morning of January 15, 2024, as the wound nurse was completing treatments on Resident 6, it was noted that the resident had an intact dressing on the left lower leg with a noted date of January 12, 2024. According to the physician's orders, the treatment to Resident 6's left lower leg wound was ordered for every other day on the day shift (7:00 a.m. to 3:00 p.m.) and should have been completed on January 14, 2024. However, as noted by the intact dressing, the treatment was not performed since January 12, 2024, per to the physician's order.

Interview with the Nursing Home Administrator on March 11, 2024, at 4:00 p.m. confirmed that Licensed Practical Nurse 1 did not complete Resident 6's treatment as ordered on January 14, 2024.

28 Pa. Code 211.12(d)(1)(5) Nursing Services.


 Plan of Correction - To be completed: 04/29/2024


1.Corrective Action
- Resident's #4 and #6 currently reside in the facility and did not have adverse effects related to inaccurate documentation of dressing change and failure to follow physician's order in regard to treatments.
- Resident #4 currently resides in the facility and did not have adverse effects related to omission of triamcinolone cream order.
- Resident #6 currently resides in the facility and did not have any adverse effects related to failure to follow physicians order for dressing changes.

2.Identifying other residents
- Residents with treatment orders have the potential to be affected by the deficient practice.
- Director of Nursing (DON)/designee shall conduct an audit of current residents with wound treatments to identify any other residents affected by the deficient practice.
- DON/designee shall conduct an audit of current residents notes to identify any errors in treatment transcription orders.

3.Systemic Changes
- DON/designee shall in-service all nurses including agency staff regarding following wound treatment orders per physician, proper documentation on the treatment administration record to ensure physician orders are followed.
- DON/designee shall in-service all Registered Nurses, including agency on transcription of treatment orders per MD

4.Monitoring
- DON/designee shall audit dressing changes for wounds to ensure accurate documentation and physician orders are followed daily x 1 week, then weekly x 4 weeks then monthly x 3 months or until compliance is achieved and maintained.
- DON/designee shall audit resident's notes for new orders to ensure order transcription is complete daily x 1 week, then weekly x 4 weeks then monthly x 3 months or until compliance is achieved and maintained.
- Audit results shall be submitted to Quality Assurance Performance Improvement for analysis and to be addressed as appropriate.

483.25(d)(1)(2) REQUIREMENT Free of Accident Hazards/Supervision/Devices:This is a less serious (but not lowest level) deficiency and is isolated to the fewest number of residents, staff, or occurrences. This deficiency is one that results in minimal discomfort to the resident or has the potential (not yet realized) to negatively affect the resident's ability to achieve his/her highest functional status.
§483.25(d) Accidents.
The facility must ensure that -
§483.25(d)(1) The resident environment remains as free of accident hazards as is possible; and

§483.25(d)(2)Each resident receives adequate supervision and assistance devices to prevent accidents.
Observations:


Based on review of clinical records and investigation reports, as well as staff interviews, it was determined that the facility failed to provide an environment that was free of accident hazards to residents who were at risk for falls for one of 10 residents reviewed (Resident 6), resulting in a fall. This deficiency was cited as past non-compliance.

Findings include:

A significant change in condition Minimum Data Set (MDS) assessment (a mandated assessment of a resident's abilities and care needs) for Resident 6, dated December 28, 2023, revealed that the resident was understood and could understand. The resident's care plan, dated November 2, 2023, revealed that he was at risk for falls related to weakness/balance problems and poor safety awareness, and required assistance but does not always ask for assistance with transfers/ambulation (walking).

Physician's orders for Resident 6, dated November 20, 2023, included an order for the resident to always have bed and chair alarms. Staff was to check the function and placement every shift.

A nursing note for Resident 6, dated November 22, 2023, at 11:55 a.m. revealed that the writer was called to the unit by staff stating that the resident had fallen. Upon entering the resident's room, the resident was found sitting on the floor on his buttocks beside his wheelchair with his back against the bed and his legs outstretched in front of him. The chair alarm was not on the resident's wheelchair at the time of the fall. The resident stated he slid out of the wheelchair. The resident was assessed for injury and was found to have no injuries. A nursing note at 12:11 p.m. revealed that the writer heard the resident hollering and found the resident on the floor in front of his wheelchair. No alarm was sounding, and there was not an alarm present. The resident was transferred out of his recliner by therapy and the alarm was not placed on his wheelchair.

A fall investigation report for Resident 6, dated November 22, 2023, revealed that upon investigation the resident's chair alarm was not under him as therapy transferred the resident into his wheelchair. Therapy was educated on the importance of ensuring that when they are transferring residents their alarms are in place.

Interview with the Nursing Home Administrator on March 11, 2024, at 5:05 p.m. confirmed that therapy transferred Resident 6 from his recliner and into his wheelchair without placing the chair alarm on the resident's wheelchair. She indicated that therapy should have placed the chair alarm on the resident's wheelchair.

Following the investigation on November 22, 2023, the facility's corrective actions included:

Therapy staff was re-educated on ensuring the placement of alarms.

A whole-house assessment was completed on residents with alarms to identify any issues.

Staff education on ensuring alarms are present was completed.

Audits were being completed to identify any issues with alarm placement.

The results of these audits will be brought to Quality Assurance Performance Improvement committee for further analysis and corrective actions if necessary.

Review of the facility's corrective actions revealed that they were in compliance with F689 on March 1, 2024.

28 Pa. Code 201.14(a) Responsibility of Licensee.

28 Pa. Code 201.18(b)(1)(e)(1) Management.

28 Pa. Code 201.24(e)(4) Admission Policy.

28 Pa. Code 211.12(d)(1)(5) Nursing Services.




 Plan of Correction - To be completed: 03/25/2024

Past noncompliance: no plan of correction required.
483.20(f)(5), 483.70(i)(1)-(5) REQUIREMENT Resident Records - Identifiable Information:This is a less serious (but not lowest level) deficiency and is isolated to the fewest number of residents, staff, or occurrences. This deficiency is one that results in minimal discomfort to the resident or has the potential (not yet realized) to negatively affect the resident's ability to achieve his/her highest functional status.
§483.20(f)(5) Resident-identifiable information.
(i) A facility may not release information that is resident-identifiable to the public.
(ii) The facility may release information that is resident-identifiable to an agent only in accordance with a contract under which the agent agrees not to use or disclose the information except to the extent the facility itself is permitted to do so.

§483.70(i) Medical records.
§483.70(i)(1) In accordance with accepted professional standards and practices, the facility must maintain medical records on each resident that are-
(i) Complete;
(ii) Accurately documented;
(iii) Readily accessible; and
(iv) Systematically organized

§483.70(i)(2) The facility must keep confidential all information contained in the resident's records,
regardless of the form or storage method of the records, except when release is-
(i) To the individual, or their resident representative where permitted by applicable law;
(ii) Required by Law;
(iii) For treatment, payment, or health care operations, as permitted by and in compliance with 45 CFR 164.506;
(iv) For public health activities, reporting of abuse, neglect, or domestic violence, health oversight activities, judicial and administrative proceedings, law enforcement purposes, organ donation purposes, research purposes, or to coroners, medical examiners, funeral directors, and to avert a serious threat to health or safety as permitted by and in compliance with 45 CFR 164.512.

§483.70(i)(3) The facility must safeguard medical record information against loss, destruction, or unauthorized use.

§483.70(i)(4) Medical records must be retained for-
(i) The period of time required by State law; or
(ii) Five years from the date of discharge when there is no requirement in State law; or
(iii) For a minor, 3 years after a resident reaches legal age under State law.

§483.70(i)(5) The medical record must contain-
(i) Sufficient information to identify the resident;
(ii) A record of the resident's assessments;
(iii) The comprehensive plan of care and services provided;
(iv) The results of any preadmission screening and resident review evaluations and determinations conducted by the State;
(v) Physician's, nurse's, and other licensed professional's progress notes; and
(vi) Laboratory, radiology and other diagnostic services reports as required under §483.50.
Observations:


Based on review of residents' clinical records, personnel files, the licensed practical nurse job description, as well as staff interviews, it was determined that the facility failed to ensure that residents' clinical records were complete and accurately documented for one of 10 residents reviewed (Resident 6). This deficiency was cited as past non-compliance.

Findings include:

The facility's licensed practical nurse job description, dated May 8, 2018, revealed that the licensed practical nurse was to chart nurses' notes in an informative and descriptive manner that reflects the care provided to the resident, as well as the resident's response to the care. Perform routine charting duties as required and in accordance with the facility's established charting and documentation policies and procedures.

Physician's order for Resident 6, dated January 10, 2024, revealed that staff was to cleanse the resident's left shin with wound cleanser, then apply Xeroform gauze (a sterile, non-adhering protective dressing consisting of absorbent, fine-mesh gauze impregnated with a petrolatum) and secure with border foam dressing (a highly absorbent self-adherent silicone foam dressing) every other day and as needed on dayshift for an abrasion (an area damaged by scraping or wearing away).

A review of Resident 6's January 2024 Treatment Administration Record (TAR) revealed that Licensed Practical Nurse 1 documented as having completed the treatment to Resident 6's left shin on January 14, 2024.

However, a review of Licensed Practical Nurse 1's personnel file revealed a disciplinary action, dated January 15, 2024, indicating that on the morning of January 15, 2024, as the wound nurse was completing treatments on Resident 6, it was noted that the resident had an intact dressing on the left lower leg dated January 12, 2024. According to physician's orders, the treatment to Resident 6's left lower leg wound was ordered for every other day on day shift(7:00 a.m. to 3:00 p.m.) and should have been completed on January 14, 2024. However, as noted by the intact dressing, this treatment was not performed since January 12, 2024. Upon further investigation, Resident 6's TAR indicated that the treatment had been completed by Licensed Practical Nurse 1 on January 14, 2024

Interview with the Nursing Home Administrator on March 11, 2024, at 4:00 p.m. confirmed that Licensed Practical Nurse 1 did not complete Resident 6's treatment as ordered on January 14, 2024, and confirmed that she documented the treatment as being completed on the resident's TAR.

Following the investigation on January 15, 2024, the facility's corrective actions included:

Licensed Practical Nurse 1 was re-educated on accurate documentation.

A whole-house assessment was completed on residents with wound treatments to identify any issues.

Staff education on the completion of treatments as ordered and documentation was completed.

Audits were being completed to identify any wound treatment/documentation issues.

The results of these audits will be brought to Quality Assurance Performance Improvement committee for further analysis and corrective actions if necessary.

Review of the facility's corrective actions revealed that they were in compliance with F842 on March 4, 2024.

28 Pa. Code 211.5(f) Clinical Records.




 Plan of Correction - To be completed: 03/25/2024

Past noncompliance: no plan of correction required.